Configuration
31
• Sunset/sunrise reaction (yes/no): Allows to control groups of lightings according to sunset/sunrise.
By entering YES in this section, this light or group of lights will be turned ON and OFF automatically at
sunset and sunrise respectively. To turn off the light or outlet before dawn, simply, use a schedule (OFF)
at the chosen time, 11 p.m for instance
NOTE: adjustment is made according to theoretical sunrise sunset for the given day. CARDIO will never
adjust lights and outlets according to the weather (cloud cover)
• Random delay for deterrent: When these lights are used in the deterrent function, it is possible to
turn them on within a random time period (0..99 minutes).
Example: turn on at 10 PM, at 65% brightness with a random delay of 6 minutes. This light (or group) will
automatically turn on at 65% brightness between 10 PM and 10:06 PM.
• Reaction: When an alarm system detector (motion, contact) is not in use, it is possible to use the
detector to activate light(s) and outlet(s) during a preset delay (0..99 minutes), at the desired intensity
(ONN OFF only for outlets) and within a preset time period.
For instance, activate the group LOBBY from the Entrance detector (zone 1) at 100% for 10 minutes from
4 p.m. and 8 a.m the following morning
Zone number: 1
Period 4:00 p.m. to 8:00 a.m.
Dim 100%
Duration: 10 minutes
Outlet
Used to name and configure outlets. The name of the outlet is very often the name of the appliance to
which it is linked.
Press outlet group to configure.