Strona 1 - User’s guide

SYSTEM VERSION 2.5xx User’s guide

Strona 2

Use of CARDIO 8 Temperature (Heating/Cooling) This feature controls temperatures for heating and, if available, air-conditioning. Temperature rea

Strona 3 - Limited warranty

Use of CARDIO 9 Scenes Cardio can control many functions at a time (lighting, alarm system, temperature, outlets, etc.). For instance, when leavi

Strona 4

Use of CARDIO 10 Modification of a scene. Press The message “Which scene do you want to modify” appears. Press the scene to be programmed or m

Strona 5 - Use of CARDIO

Use of CARDIO 11 How to add new data to an already programmed scene Press The new screen which appears is identical to the main screen sho

Strona 6 - General

Use of CARDIO 12 Automatic activation of a scene Press The following screen appears: Besides the touch screen, a scene can be call

Strona 7 - Lighting

Use of CARDIO 13 Outlets / Appliances From the main menu press The following screen appears: CARDIO can control appliances plugged

Strona 8 - Security

Use of CARDIO 14 S.O.S Cardio can send out emergency calls in case of emergency. See “Control by telephone” for more detail on these calls. Fro

Strona 9

Programming 15 Programming In addition to direct control of basic functions, the user is able to program all of these functions to respond automa

Strona 10

Programming 16 Log book Indicates the last 100 events related to the alarm system (break-in, fire, medical, overheating, freezing, battery status

Strona 11 - NOTE p.11

Programming 17 Functions (on/off) CARDIO allows the user to temporarily deactivate any programmed functions without erasing the programming itsel

Strona 12 - Modification of a scene

LIMITED WARRANTY ... 1 USE OF CARDIO...

Strona 13

Programming 18 Date and time Adjustment of date and time settings. It is very important that both the time and date be set correctly because all

Strona 14

Programming 19 Scheduling How to schedule CARDIO allows the scheduling of certain functions such as deterrent reminders, in addition to thos

Strona 15 - Outlets / Appliances

Programming 20 Reminders Just as an alarm clock, CARDIO can signal (with beeps) a variety of events at specific times. It also can call up on th

Strona 16

Programming 21 Deterrent scheduling CARDIO can simulate a presence in the home when the alarm system is armed. It turns ON and OFF lights at sche

Strona 17 - Programming

Programming 22 The following screen appears: Adjust lights to the desired intensity and press If desired, adjust the cursor

Strona 18 - Log book

Programming 23 Light scheduling From programming menu press The following screen appears: Choose a group of lights The following scre

Strona 19 - Functions (on/off)

Programming 24 The following screen appears: Adjust lights to the desired intensity and press. If desired, place the cursor to a new t

Strona 20 - Date and time

Programming 25 Outlets scheduling CARDIO can also schedule outlets to be turned ON and OFF. From programming menu press The following screen a

Strona 21 - Scheduling

Programming 26 Alarm system scheduling CARDIO can arm and disarm the alarm system according to previously set days and time. Refer to the section

Strona 22 - Reminders

Programming 27 Particularity When programming the disarming of the alarm system, the screen, which appears, does not include zones. Enter an acce

Strona 23 - Deterrent scheduling

Limited warranty 1 Limited warranty We appreciate your purchase of a Secant Home Automation Inc. product. We take pride of our products and they are

Strona 24 - Precise adjustment buttons

Configuration 28 Configuration The configuration menu that can be accessed from the programming menu let the user adjust and modify some data r

Strona 25 - Light scheduling

Configuration 29 Moves Arrows to move the cursor (black triangle) forward or backward Quick move arrow (forward only) Modification of a data

Strona 26 - Fast adjustment bar

Configuration 30 Light Used to name and configure groups of lights Press lamp icon and the following screen appears: Press the group

Strona 27 - Outlets scheduling

Configuration 31 • Sunset/sunrise reaction (yes/no): Allows to control groups of lightings according to sunset/sunrise. By entering YES in this s

Strona 28 - Alarm system scheduling

Configuration 32 The following screen appears: • X-10: Enter the X-10 code to be attached to the outlet • NAME: Press EDIT and enter

Strona 29 - Temperature scheduling

Configuration 33 Codes Used to name and configure security zones as well as to enter various access codes. • Code (1 to 8): Enter h

Strona 30 - Configuration

Configuration 34 Digital keys Allows the configuration of the electronic keys. To declare a digital key, use arrows to position the pro

Strona 31 - Modification of a data

Configuration 35 Telephone Used to configure the control of Cardio by telephone from anywhere outside the home. Also used for programming number

Strona 32

Configuration 36 Zone names “BEEP” Used to name security zones • NAME (1 to 16): Name of the zone. • BEEP (yes/no): Beep when a dete

Strona 33 - Outlet

Control by telephone 37 Control by telephone In addition to the ease of use offered by Cardio’s touch screen, the system can also be controlled b

Strona 34

Limited warranty 2 THE SOFTWARE, HARDWARE, AND DOCUMENTATION IS PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, BUT NOT LIM

Strona 35

Control by telephone 38 Telephone operation diagram

Strona 36 - Delays

Recommandations et maintenance 39 Recommendations and maintenance Here a list of functions and appliances that must be checked in order to secure

Strona 37 - Telephone

Industry Canada warnings 40 Industry Canada warnings The Industry Canada Label identifies certified equipment. This certification means that the

Strona 38 - Zone names “BEEP”

1744, William street, suite 401 Montréal, Québec, H3J 1R4 Tel: (514) 935-3069 Fax: (514) 935-6655 email: [email protected] www.secant.ca Seca

Strona 39 - Control by telephone

Use of CARDIO 3 Use of CARDIO Introduction The Cardio home automation system enables homeowners to better manage such basic functions as heating

Strona 40 - Telephone operation diagram

Use of CARDIO 4 Presentation of system CARDIO Cardio’s screen shuts down after being idle for one minute. It is easy to reactivate by pressing an

Strona 41

Use of CARDIO 5 Lighting Control groups of lights linked to Cardio (ON/OFF, dim). Each group can be made up of many lights. From the main menu

Strona 42 - Industry Canada warnings

Use of CARDIO 6 Security Controls the arming and disarming of the alarm system. From the main menu press The following screen appears:

Strona 43 - Montréal, Québec, H3J 1R4

Use of CARDIO 7 To bypass zones, simply press the zones to be ignored (these zones are now crossed out) Press to return to

Komentarze do niniejszej Instrukcji

Brak uwag