HVAC System
Made up of two separated items, a furnace and a cooler, controlled by a single thermostat with two set
points. Four modes of operation (none, heating only, cooling only and automatic) and fan control
(automatic, manual). CARDIO in the HVAC settings can substitute this thermostat.
ATTENTION!: its is impossible to have both heating and cooling at the same time in the HVAC
mode. There is always a 2-degree minimal difference between the two settings and CARDIO will
adjust automatically if necessary.