Advance configuration
13
• Temperature offset: because of the particular location of the touch panel, the temperature at the
thermostat may vary from the average zone temperature. Therefore it is possible to adjust the reading
displayed on screen (or on the phone). The maximum temperature compensation is +/- 9.9 degrees
Celsius or Fahrenheit.
Ex: a thermostat has been installed in a central location near the kitchen. With no compensation, the
temperature reading (the exact temperature) at this location is 70F while the average temperature in the
dining room and the living room is 72F. If the temperature the user wants to read and monitor (schedules,
scenes, etc.) is the temperature in the living room, just enter +2. Therefore, the screen will display 72
instead of 70.
ATTENTION!: the temperature control performed by CARDIO is based on the temperature
offset. Therefore it is very important to set this parameter correctly.
• Hysteresis: used mainly with heating/cooling system based on pulsed air. Say that the screen is
located in a central location but near a heating/cooling bay. With no adjustment, the temperature read
at the screen will always get to the desired temperature much before the average temperature in the
room. Then, the heating/cooling system would always be turned ON/OFF (cycling) on a very short
time basis before the average room temperature is reached.
Adjusting the system gives more inertia to the temperature control
. Maximal temperature adjustment
goes from +/-0.1 degree Celsius or Fahrenheit to +/- 42 2.9 degrees Celsius or Fahrenheit. Temperature
readings on screen will always be the exact temperature as read by the thermostat. Then, with a 2F
adjustment, temperature readings will go to 74F before the system turns off the heat if the desired
setting is 72F.
• CARDIO control type: select the type of heating (cooling) system to be controlled by CARDIO:
1. Central heating:
2. Heat pump RC:
3. HVAC:
4. Heating setback:
5. HVAC setback:
6. Heat pump RH:
7. Heat/cool:
8. None:
• Secondary controller: when available, choose from RCS or Statnet HVAC controllers. Also, enter
number of secondary zones to be controlled (1 with RCS and up to 4 with Statnet). Do not include
here the zone controlled by CARDIO’s thermostat.
• Zone name: press EDIT and enter name of zones (up to 5) to be controlled.
• Freeze detection (yes/no): is CARDIO to detect a minimum temperature and send out an alert? (see
temperature setting below)
• Overheat detection (yes/no): is CARDIO to detect a maximum temperature and send out an alert?
(see temperature setting below)
• Freeze temperature: enter the minimum temperature threshold.
• Overheat temperature: enter the maximum temperature threshold.
!WARNING!: DO NOT USE CARDIO FOR FREEZE PROTECTION. We strongly
recommend to install an auxiliary mechanical freeze protection for this purpose.